ASCAIRCLEANING.COM
Sales, Installations & Servicing of Industrial Air Purification Equipment

15 North Washington Street Plainville, CT 06062
Toll Free: 866-619-7686
Fax: 860-747-3989
                     




T1300





T2600








T5200

These three units use electrostatic precipitation technology to
remove 95% of air born particles such as smoke, fumes, and
oil/coolant mist.  These units utilizes the principle of electrostatic
precipitation.  The particles pass into a strong electrical field
where the particles receive an electrical charge, then the particles
pass through the collection plates which are grounded and attract
the particles. These units can be hung from the factory ceiling for
ambient air collection, or ducted for source capture.

These units clean, then recirculate already conditioned air back
into the work area.  It can take as much as four times the amount
of energy to condition outside "make up air" to replace exhaust air
as it does to clean and recycle previously conditioned air.  CFM
ratings, 1300, 2600, 5200 respectively.
                 






T1001







T2002
     Trion Mini M.E.


High efficiency electrostatic modules for in-duct installation where air
movement is provided by other external sources.
 

These three units use electrostatic precipitation technology to remove 95%
of air born particles such as smoke, fumes, and oil/coolant mist  These
units can be hung from the factory ceiling for ambient air collection, or ducted
for source capture.

These units clean, then recirculate already conditioned air back into the work
area.  It can take as much as four times the amount of energy to condition
outside "make up air" to replace exhaust air as it does to clean and recycle
previously conditioned air.

Designed to remove oil/coolant mist and smoke at the source.  This unit utilizes the principle of
electrostatic precipitation.  The particles pass into a strong electrical field where the particles receive an
electrical charge, then the particles pass through the collection plates which are grounded and attract the
particles.  T
his unit can be mounted directly on the machine.  The inlet is located on the bottom of the
machine.  The air is pulled upwards and cleaned.  
No duct work is needed. CFM rating of 756.
Trion Mini M.E. connected to a CNC machine for source capture.
VOMP 600
Remove oil & coolant mist at the source.  The unit
draws polluted air through its impinger, which strips
micron particles from the air steam by impaction.  The
remaining particles travel through a secondary filter
and then through the 95% DOP rated primary filter
which strips smoke and other submicron particles
from the air steam by interception.  CFM rating 600.
The Vomp 600 is a vertical, electrostatic based
coolant mist collector designed for OSHA and
EPA compliance. The VOMP 600 can be ducted
directly to the machine tool for source capture of
contaminants such as water-soluble, synthetic
and petroleum-based coolants and smoke.  ESP
based coolant mist collectors are most effective at
a low CFM.
The MP2400M is great for trapping contaminants such as water soluble,
synthetic and petroleum-based coolants, and grinding dust generated
from operations such as screw machines, surface and centerless
grinders, CNC, turning lathes, parts cleaning systems, etc.

Remove oil & coolant mist at the source.  The unit draws polluted air
through its impinger, which strips micron particles from the air steam by
impaction.  The remaining particles travel through a secondary filter
and then through the 95% DOP rated primary filter which strips smoke
and other submicron particles from the air steam by interception.  CFM
rating 2400.
MP2400
MP 600M
OIL MIST  & SMOKE Collection Page:  

All the units listed on this page can be used for Cold heading, wet mist collection, wire EDM fumes,
Extrusion, screw machining emissions, soldering emissions, welding smoke & rubber smoke emissions.

 
NO
DUCT
WORK
NEEDED
NO
DUCT
WORK
NEEDED
-Abbreviated Specifications-
For the F62B Electronic Air Cleaners
(download PDF at bottom for full specifications)
Power Input:  120 Vac, 60 Hz, Single Phase 8.7 Amps
208-240 Vac, 60 Hz, Single Phase, 3.9 Amps
208-240 Vac, 60 Hz, Three Phase, 3.4 Amps
440-480 Vac, 60 Hz, Three Phase, 1.7 Amps
Electronic Cells:  2 included providing 218 square feet of surface area
Efficiency: Up to 95% based on ASHRAE 52-76 test method
Power Supply:  Self-regulating, dual voltage, industrial rated power
supply
Motor: 3/4 hp maintenance free motor.  
Accessories: Optional Canopy Hood, Drain Pan, Remote Control Kit and
Carbon Filter
AIR QUALITY ENGINEERING F62B
Mist Buster 850 Triple or Double Pass
has three or two industrial grade
power supplies and specially
designed cells to remove heavy mist
and smoke from enclosed CNC
machines. Unlike copycat models that
use cells designed for household air
cleaners, we manufacture our own
cells to withstand heavy duty
industrial mist collection applications.
The MB 850 has the same footprint
as the original MB 500 and is
completely interchangable. We can
even add a third stage filter cell and
separate power supply in the same
package, if your high pressure spray
is upwards of 1800 psi, or if you have
multiple conveyor openings!

To prove our point, try one at no
charge for 30 days and see why the
MistBuster Series has become the
chioce of most OEM,s and end user
customers in the Machine Tool
Industry!!!
AQE MistBuster Units:  Used for source capture applications
ASC INDUSTRIAL AIR CLEANING SOLUTIONS:
Sales, Installations & Servicing of Industrial Air Purification Equipment
15 North Washington Street Plainville, CT 06062
Toll Free: 866-619-7686
Fax: 860-747-3989
Home Page         Electrostatic Servicing        Trion Parts        Aercology Parts         Absolent  Filters        Air Quality Eng Parts         Smog Hog Parts  
CLICK HERE FOR A MISTBUSTER DEMONSTRATION VIDEO