ASCAIRCLEANING.COM Sales, Installations & Servicing of Industrial Air Purification Equipment
15 North Washington Street Plainville, CT 06062 Toll Free: 866-619-7686 Fax: 860-747-3989
|
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
The Vomp 600 is a vertical, electrostatic based coolant mist collector designed for OSHA and EPA compliance. The VOMP 600 can be
ducted directly to the machine tool for source capture of contaminants such as water-soluble, synthetic and petroleum-based coolants and
smoke. ESP based coolant mist collectors are most effective at a low CFM.
Dry Particulate Collection:
You can remove dry particulate from the air in one of two ways:
Air Boss® T Series Electrostatic Blowerless Units: High efficiency electrostatic modules for in-duct installation where air
movement is provided by other external sources.
Air Boss® Media Filter Units: Trion’s AIR BOSS media units are industrial air cleaners designed for both
general ventilation (removal of airborne pollutants from plant atmospheres) or source capture (ductwork or arms
positioned at the origin of pollutants). These units help solve welding smoke, oil mist, rubber dust, diesel
smoke, grinding dust, numerous gases/odors and many other indoor air pollution problems.
Features/Benefits
- Straight through or side discharge — ability to better control airflow (M3000 & M6000)
- Odor and High Efficiency Filters — from HEPA and adsorber modules to mini-pleat filters (194/388 sq. ft.)
for maximum efficiency and effectiveness (M3000 & M6000)
- Belt driven blower with variable pitch sheave — providing adjustment for precise CFM operating range
(M3000 & M6000)
- Collects wet or dry particulates providing versatility in a wide range of applications (M3000 & M6000)
- High static blower packages — capacity for additional external static offers more contaminant pickup
points (optional for M3000)
How It Works
Trion’s Air Boss Media Series uses the Interception Filtration Principle. Dirty, polluted air is drawn through the
pre-filter to remove larger dust particles. The second stage, micro-glass deep pocket media filter removes
submicron particles from the air stream by interception. The small diameter fibers in the filter intercept and retain
these small particles while the large surface area of the filter gives long life and low pressure drop. The blower is
designed specifically to handle the filtration system at rated CFM over the useful life of the filter.
_____________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
The big advantage with the VOMP 600 is that very little duct work is needed.
|
The second way of removing dry particulate is by pulling the contaminated air through a media filter.
|
The first way is through electrostatic technology: The contaminates in the air are electrically charged as they pass through an ionizer section. The contaminates are then attracted to collection plates as they pass through an aluminum collection cell. You must wash the collection plates, there are no filters to replace. These Trion units are ideal for the removal of smoke, fumes, and oil/coolant smoke and mist. The T Series has the ability to clean contaminated indoor air and recirculate it back to the work area, reducing energy costs by not having to exhaust conditioned air to the outside. Any of the T Series can be installed free hanging or ducted for source capture. It comes in three sizes, the T1300 (1300CFM), the T2600 (2600 CFM), & the T5200 (5200CFM).
|
ASC INDUSTRIAL AIR CLEANING SOLUTIONS: Sales, Installations & Servicing of Industrial Air Purification Equipment 15 North Washington Street Plainville, CT 06062 Toll Free: 866-619-7686 Fax: 860-747-3989
|